CEE 690K

Environmental Reaction Kinetics

 

Homework #1

 

The city of Gardenia, NJ needs your help.  They would like to develop a new groundwater source.  Like many groundwaters this one has high levels of iron.  They have proposed a small treatment system using fine bubble aeration.

a.      If they design this groundwater source to provide a maximum of 3 MGD, how much air would need to be supplied?  (in mg/L and m3/h)

b.     How large would the contactor have to be if they wished to remove iron down to 15% of its initial concentration? (in m3).  Assume that the dissolved oxygen level reaches saturation (10 mg/L) very rapidly in the contactor.  Also assume that the water temperature is 20ēC.

 

 

State any additional assumptions.  Feel free to consult any water chemistry references (e.g., Stumm & Morgan; Snoeyink & Jenkins), or any other literature that you feel would be of help.

 

 

Groundwater Quality

Ion

Conc (mg/L) or pH

Sodium

8.2

Potassium

1.4

Calcium

92

Magnesium

34

Bicarbonate

339

Nitrate

13

Sulfate

84

Chloride

9.6

pH

6.72

Iron

0.66

 

 

Assigned: 7 Feb 08

Due: 14 Feb 08